As the professional manufacturer, we would like to provide you Rack-Mounted Cooling Air Conditioner. The CPSY® SPR Series Rack-Mounted Cooling Air Conditioner units are a great way to improve the comfort and productivity of your home or office. They can also help to reduce energy costs and improve the lifespan of your equipment. If you are looking for a way to improve your indoor environment, a precision air conditioning unit is a great option to consider.
As the professional manufacturer, we would like to provide you Rack-Mounted Cooling Air Conditioner. For scenarios such as small, micro or distributed IT cabinets, computer rooms, data centers, etc., CPSY® has developed the SPR series of Rack-Mounted Cooling Air Conditioners based on the small precision air conditioner series. This product is highly energy-saving, has low power consumption, small size, compact structure, light weight, excellent value, flexible configuration, takes up less space, simple installation and quiet operation. It can accurately handle the high sensible heat generated by servers in the cabinet and effectively prevent Local hot spots, making it ideal for small and medium-sized applications. Whether in data centers, clean rooms, laboratories or telecommunications facilities, the CPSY® SPR Series rack-mounted cooling air conditioners provide optimal performance in all operating conditions and ensure 24/7 availability, especially suitable for the SG era. Single cabinet, multiple cabinets and other high heat density application environments.
Type | Single cold source | Constant Temperature & Humidity | |||||
Indoor model | SP04R1(Not equipped with water pump) | SP08R1(Not equipped with water pump) | SP12R1(Not equipped with water pump) | SP04R1H(Standard water pump) | SP08R1H(Standard water pump) | SP12R1H(Standard water pump) | |
outdoor model | SP04W1 | SP08W1 | SP12W1 | SP04W1 | SP08W1 | SP12W1 | |
EER | 3.18 | 3.21 | 3.2 | 3.18 | 3.21 | 3.2 | |
Power Specifications | 220VAC/50HZ | ||||||
Max current | 7 | 15 | 25 | 12 | 20 | 35 | |
Input breaker(suggestion) | 16A/2P | 25A/2P | 40A/2P | 16A/2P | 25A/2P | 40A/2P | |
Indoor unit cable (suggestion) | 3*2.5mm2 | 3*4mm2 | 3*6mm2 | 3*2.5mm2 | 3*4mm2 | 3*6mm2 | |
Outdoor unit cable (suggestion) | 3*1.5mm2 | 3*2.5mm2 | 3*4.0mm2 | 3*1.5mm2 | 3*2.5mm2 | 3*4.0mm2 | |
Internal and external unit signal lines (suggestion) | Shielded wire:2*0.75mm2 | ||||||
cooling capacity(kW) | 3.5 | 7.5 | 12.5 | 3.5 | 7.5 | 12.5 | |
Sensible cooling capacity(kW) | 3.5 | 7.5 | 12.5 | 3.5 | 7.5 | 12.5 | |
sensible heat ratio | 1 | ||||||
discharge airflow(m3/h) | 800 | 1650 | 2200 | 800 | 1650 | 2200 | |
Return air volume(m3/h) | 800 | 1650 | 2200 | 800 | 1650 | 2200 | |
PTC electric heating power(kW) | / | / | / | 1 | 1 | 2 | |
Wet film humidification capacity (kg/h) | / | / | / | 1 | 1.5 | 3 | |
Compressor | Compressor QTY. | 1 | |||||
Fixed/variable frequency | DC variable frequency | ||||||
Compressor Type | Rotor compressor | ||||||
Indoor fan | Fan QTY | 2 | 1 | 1 | 2 | 1 | 1 |
Fan Type | EC centrifugal fan | ||||||
Outdoor fan | Fan QTY | 1 | 1 | 2 | 1 | 1 | 2 |
Fan Type | Axial fan | ||||||
Evaporator | \ | ||||||
Thermostatic Expansion Valve | Type | Electronicexpansion valve | |||||
Fliter | Fliter level | G2 level | |||||
Refrigerant(Copper pipes within 5 meters are available) | Type | R410A | |||||
Factory precharge of indoor unit(kg) | 0.5 | 0.85 | 1.2 | 0.5 | 0.85 | 1.2 | |
Factory precharge of indoor unit(kg) | 0.5 | 0.85 | 1.2 | 0.5 | 0.85 | 1.2 | |
Noise value(dB) | Indoor Unit | 65 | 69 | 72 | 65 | 69 | 72 |
Outdoor Unit | 61 | 62 | 62 | 61 | 62 | 62 | |
Dimensions(mm)(W*D*H) | Indoor Unit(W*D*H) | 443*715*218(5U) | 443*715*351(8U) | 443*715*440(10U) | 443*715*218(5U) | 443*715*351(8U) | 443*715*440(10U) |
Outdoor Unit(W*D*H) | 765*268*550 | 960*370*810 | 960*370*1260 | 765*268*550 | 960*370*810 | 960*370*1260 | |
Weight(kg) | Indoor Unit | 27 | 36 | 42 | 27 | 36 | 42 |
Outdoor Unit | 30 | 60 | 85 | 30 | 60 | 85 | |
Size for takeover(mm)(suggestion) | Air pipe (not equipped with copper pipe at the factory) | 9.52 | 15.88 | 15.88 | 9.52 | 15.88 | 15.88 |
Liquid pipe (not equipped with copper pipe at the factory) | 6.35 | 9.52 | 6.35 | 9.52 | |||
water inlet pipe | \ | G1/2" | |||||
drain pipe | The natural drainage pipe is OD25*ID19 mm | The natural drainage pipe is OD25*ID19 mm, and the strong drainage pipe is OD8*ID5mm. | |||||
Allowable length of takeover(m) | Equivalent length of internal and external machine pipes | ≤20 | |||||
Difference in installation position between indoor and outdoor units | The outdoor unit is higher than the indoor unit≤10 | ||||||
The outdoor unit is lower than the indoor unit≤5 | |||||||
Design usage conditions | Indoor ambient temperature 35℃/wet bulb temperature 27℃; outdoor ambient temperature 35℃ | ||||||
Standard (functional) parts | Comes with a 4.3-inch display, 1 temperature and humidity sensor, 1 temperature sensor, and 1 water leak detector | ||||||
Optional (functional) parts |
1. Extension component (if the single-way pipeline length exceeds 20 meters, an oil trap needs to be added every 5 to 7.5 meters), the maximum extension is 30m; 2. Low-temperature components (configured in areas where the outdoor temperature is lower than -15°C), can reach -35°C after configuration. |
||||||
Features |
1. Multiple distribution and drainage design (natural drainage, pump strong drainage optional); 2. Power-off memory, self-starting upon incoming call; 3. Intelligent protection: power supply phase loss, over-voltage and under-voltage, reverse phase protection alarm, unit water leakage protection, compressor high and low voltage protection alarm, high/low temperature alarm in the machine room environment. 4. Storage of 200 historical records. |
CPSY® SPR series Rack-Mounted Cooling Air Conditioner 1-40KVA ups
Model No.:GP1101K/GP1102K/GP1103K/GP1106K/GP1110K/GP1115K/
Cooling Air Conditioner power range: 1KVA~40KVA
The CPSY® SPR series is the first EIA-compliant Rack-Mounted Cooling Air Conditioner system specifically designed to cool IT equipment in data centers, server rooms and network closets.
--Fully variable frequency design, energy efficiency ratio can reach 3.5;
--Ultimate space utilization efficiency, more users can use U space;
---Powerful drainage pump assembly to eliminate "water danger" in the cabinet
--Microcomputer intelligent control system, real-time monitoring;
--Intelligent control can realize early warning;
--The indoor and outdoor units are pre-installed with quick connectors and pre-filled with refrigerant at the factory. They can be installed on-site without welding.
--Independent, built-in evaporator, no floor drain required
--1 year limited warranty
--Supports optional remote management via Ethernet
--Mounts in the bottom of an EIA standard 19-inch rack
--Saving energy through efficient close-coupled cooling
--Prevent equipment shutdowns and failures caused by overheating and temperature fluctuations
Industrial environments, medical facilities, laboratory equipment, etc. are key equipment for power supply and protection.
Application
Servers.
Educational Institutes.
BFS
Healthcare Systems.
Telecommunication Equipments.
Small & Medium Data Centers.
CNC Machines.
Pharmaceutical Appliances.
X-ray Machines.
Industrial Facilities.
When compare with peers, CPSY® SPR series Rack-Mounted Cooling Air Conditioner advantages as below:
There are several benefits to using a precision air conditioning unit. Some benefits include:
1. Improve comfort
Precision air conditioning units can reduce the impact of heat and humidity on the body by setting constant temperature and humidity, creating a more comfortable environment for people in the room.
2. Reduce energy costs
Precision air conditioning units can be programmed to operate in high-efficiency and energy-saving modes to reduce energy costs
3. Increase productivity
Precision air conditioning units can create a more comfortable and efficient environment for workers, helping to increase productivity.
4. Reduce downtime
Precision air conditioning units can be programmed to operate on and off, reducing the risk of equipment failure and reducing downtime.
5. Improve living environment
Precision air conditioning units can help improve the environment in many ways (such as reducing the use of fossil fuels, reducing the amount of pollution produced, reducing people's stress and anxiety), thus improving their overall quality of life.
1. High-performance components eliminate the risk of "hot spots"
The three-side air supply design can effectively prevent the occurrence of "local hot spots". After the unit is installed, it can realize air supply from the left, right and top sides, and local hot spots can be eliminated in the budding stage.
2. High-efficiency cooling coil design, durable and energy-saving
Compared with traditional fin coils, all-aluminum microchannel cooling coils are less prone to clogging and bacterial growth, helping to improve air quality and simplify equipment maintenance, helping to improve heat transfer efficiency, reduce fan power consumption and reduce overall unit weight. The hydrophilic film aluminum fan low-pressure loss fins are perfectly combined with internally threaded copper tubes. The innovative CFD-assisted optimization design greatly improves the heat exchange efficiency of the heat exchanger, making it durable and energy-saving. With micro-channel coils, the CPSY® SPR Series rack-mounted cooling air conditioners set new cooling standards for sensitive applications such as semiconductor manufacturing, IT cooling, medical, pharmaceutical, food sterilization and more.
3. High performance air filter
Optional anti-fouling surface treatment and high-performance air filters (filtration rating up to ISO ePM1 90%) ensure the highest indoor air quality for users of CPSY® SPR Series rack-mounted cooling air conditioners.
4. Powerful and simple system management control software
The CPSY® SPR series rack-mounted cooling air conditioning control system is the latest generation of controllers with logic developed specifically for chilled water air handlers. The software provides advanced control capabilities for stand-alone and network operation, local or remote monitoring and diagnostic functions. Users can employ various control strategies based on continuous temperature control, on-demand air flow control or constant pressure control.
5. Flow control
The CPSY® SPR Series rack-mounted cooling air cooling systems are highly adaptable to changing loads. The system continuously measures the thermal parameters of the cooling space and uses a two-way valve system to regulate the flow of water through the cooling coil and bypass. With an intelligent balancing system, commissioning time and maintenance costs can be significantly reduced and normal operation of the system guaranteed.
6. Back-inclined EC centrifugal fan
CPSY® SPR series rack-mounted cooling air conditioning units use backward-inclined EC centrifugal fans and are equipped with radial fans. New manufacturing processes and new materials are perfectly applied to core components. The aerodynamic performance is greatly enhanced, and it has the characteristics of high intelligence, low power consumption, long life, small vibration, low noise, and quiet operation. EC motors smoothly control airflow based on actual cooling needs and also help achieve energy savings not possible with AC-driven fans.
7. High-quality electronic expansion valve, precise control
PID ultra-precision control technology perfectly matches the variable frequency compressor and EC fan to accurately adjust the refrigerant circulation flow, making the equipment run more smoothly throughout its life cycle and saving 1% in overall energy.
Q1: What is precision air conditioner?
A1: A precision air conditioning unit is an air conditioning system designed to precisely control the temperature and humidity of a room. Precision air conditioning units are typically larger and more complex than traditional air conditioning units. They often feature multiple zones that can be controlled independently, and can be equipped with a variety of sensors and controllers to provide precise control of temperature and humidity. They are often used in critical applications where even small changes in temperature or humidity can have a significant impact on equipment or people in the room.
Q2: How does precision air conditioning work?
A2: Precision air conditioning units maintain a comfortable and consistent environment for the people and equipment in the room by using various sensors and controllers to monitor and regulate the temperature and humidity of the air circulating in the room.
Q3: How to choose a precision air conditioner that suits your needs?
A3: When choosing a precision air conditioner, you need to consider the following factors:
1. Room Size: The size of the room will determine the size of air conditioning unit you need.
2. Type of equipment in the room: The type of equipment in the room will determine the type of air conditioning unit you need. For example, if there are many computers in the room, you will need an air conditioning unit that can handle the heat generated by the computers.
3.Climate: The climate will determine the type of air conditioning unit you need. For example, if you live in a hot climate, you will need an air conditioning unit that can effectively cool the room.
4. Your budget: Precision air conditioning unit prices vary based on size, type, and climate.
5. Reviews: It's important to do your research and read reviews before purchasing.
Q4: How to maintain precision air conditioners?
A4: The following measures can be taken for precision air conditioning maintenance:
1. Clean the filter in time: The filter in the precision air conditioning unit should be cleaned regularly to ensure the clean and efficient operation of the equipment and reduce operational risks.
2. Calibrate equipment regularly: Equipment should be calibrated regularly to ensure that the equipment is operating at its best.
3. Check equipment regularly: Equipment should be checked regularly to see if it is in good condition and any problems can be discovered and repaired quickly.
Q5: How to troubleshoot precision air conditioners?
A5: You can troubleshoot precision air conditioning units in the following ways:
1. Check the filter: The filter in the precision air conditioning unit should be checked regularly to see if it is dirty and cleaned regularly to prevent the equipment from running effectively.
2. Check the thermostat: Regularly check whether the thermostat in the precision air conditioning device is working properly and maintain a constant temperature.
3. Check the refrigerant: The refrigerant in the precision air conditioning unit should be checked regularly to avoid insufficient refrigerant.